Journal Home
Search for

Volume 10, Issue 4, Pages 252-254 (October 2009)


View previous. 8 of 58 View next.

Multiple coronary artery aneurysm formation one year and four years after sirolimus-eluting coronary stent implantation

Kenan Övünç, Hikmet YorgunCorresponding Author Informationemail address, Necla Özer

Received 15 September 2008; accepted 26 September 2008.

Abstract 

A 61 years old male patient having the complaint of angina pectoris underwent coronary angiography that revealed critical luminal stenosis at left anterior descending artery (LAD) and diagonal branch. Percutaneous transluminal coronary angioplasty was performed and sirolimus eluting stents (CYPHER; Johnson & Johnson – Cordis) 2.75 ×10 mm and 2.75×10 mm were deployed respectively. One year after the procedure coronary angiography revealed coronary artery aneurysm (CAA) formation in diagonal branch and mild ectasia in LAD stent area. Last coronary angiography four years and three months after initial intervention showed multiple CAA at diagonal branch and LAD. This case report is an example of late formation of CAA by sirolimus-coated coronary stent.

Department of Cardiology, Hacettepe University, Ankara, Turkey

Corresponding Author InformationCorresponding author.

PII: S1553-8389(08)00288-1

doi:10.1016/j.carrev.2008.09.005


View previous. 8 of 58 View next.