« Previous
Next »
Cardiovascular Revascularization Medicine
Volume 10, Issue 4
, Pages 216-220
, October 2009
Early and mid-term clinical outcomes with the CATANIA coronary stent system vs. bare metal stents in patients with coronary artery disease
References
- . A new polymer concept for coating of vascular stents using PTFEP (poly(bis(trifluoroethoxy)phosphazene) to reduce thrombogenicity and late in-stent stenosis. Invest Radiol. 2005;40:210–218
- . First-in-man one-year clinical outcomes of the CATANIA coronary stent system with nanothin Polyzene-F in de novo native coronary artery lesions: Assessment of The LAtest Non-Thrombogenic Angioplasty Stent (ATLANTA) Trial. J Am Coll Cardiol Intv. 2009;2:197–204
- Guidelines for percutaneous coronary interventions. The Task Force for Percutaneous Coronary Interventions of the European Society of Cardiology. Eur Heart J. 2005;26:804–847
- . Academic Research Consortium. Clinical end points in coronary stent trials: a case for standardized definitions. Circulation. 2007;115:2344–2351
- . APPROACH (Alberta Provincial Project for Outcome Assessment in Coronary Heart Disease) Investigators. Comparison of 2 methods for calculating adjusted survival curves from proportional hazards models. JAMA. 2001;286:1494–1497
- . Are drug-eluting stents superior to bare-metal stents in patients with unprotected non-bifurcational left main disease? Insights from a multicentre registry. Eur Heart J. 2009;30:1171–1179
- . Optical coherence tomography results at six month follow-up evaluation of the CATANIA coronary stent system with nanothin Polyzene-F surface modification (from the Assessment of The LAtest Non-Thrombogenic Angioplasty Stent [ATLANTA] Trial). Am J Cardiol. 2009;103:1151–1155
- . Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation. 2007;115:2435–2441
- . Restenosis of the CYPHER-Select, TAXUS-Express, and Polyzene-F nanocoated cobalt-chromium stents in the Minipig Coronary Artery Model. Cardiovasc Intervent Radiol. 2007;31:971–980
- . Meta-analysis comparing drug-eluting stents with bare metal stents. Am J Cardiol. 2005;95(5):640–643
- . Mortality in randomized controlled trials comparing drug-eluting vs. bare metal stents in coronary artery disease: a meta-analysis. Eur Heart J. 2006;27(23):2784–2814
PII: S1553-8389(09)00242-5
doi: 10.1016/j.carrev.2009.07.001
© 2009 Elsevier Inc. All rights reserved.
« Previous
Next »
Cardiovascular Revascularization Medicine
Volume 10, Issue 4
, Pages 216-220
, October 2009
